PS Audio Power Plant P5

$5,695

Brand PS Audio

P5 Power Plant

Generate new AC power for best performance

Built in Boulder

Power Plants take your incoming AC power and regenerates new sine-wave-perfect, regulated high current AC power. In the process of regeneration any problems on your power line such as low voltage, distorted waveforms, sagging power and noise are eliminated. The results are both audibly and visually stunning when powering either audio or video products.

Features:

  • 1200 VA output
  • Built in Boulder
  • Surge protection
  • Spike protection
  • Regulated output voltage
  • Ten times lower distortion
  • Whisper cooling fan
  • 100% regenerated AC
  • Integrated oscilloscope
  • THD meter
  • Control over the web or network
  • Adjustable output voltage

Specifications:

 

Environment Specification

US/JP

Europe/Asia

Location Indoor use only Indoor use only
Duty Cycle Suitable for continuous operation Suitable for continuous operation
Moisture Sensitivity Not sealed against moisture Not sealed against moisture
Operating Humidity <80%rh <80%rh
Storage Temperature -40C to +40C -40C to +40C
Operating Temperature 0C to 40C 0C to 40C
Max Operating Altitude 12,000’ (3500m) 12,000’ (3500m)
Electrical Supply Nominal Rating 120V 15A 60Hz US
100V 15A 50/60 Hz JP
230V 10A 50/60Hz

Instrument Specification

Unit Dimensions 17” W x 14” D x 4” H (43cm W x 36cm D x 10.16 cm H) 17” W x 14” D x 4” H (43cm W x 36cm D x 10.16 cm H)
Unit Weight 37 lbs ( 16.7kg) 37 lbs ( 16.7kg)
Shipping Dimensions 24” x 21” x 10” ( 61cm x 53cm x 25cm) 24” x 21” x 10” ( 61cm x 53cm x 25cm)
Shipping Weight 48 lbs (21.7kg) 48 lbs (21.7kg)
Nominal Input Voltage 95 – 145 VAC 200 –285VAC
Maximum Continuous Load 1000VA 1500VA
Maximum Peak Load 1200VA 1800VA
Voltage Regulation 0.5V 1V
Output Distortion (Resistive Load) <0.5% <0.9%
Output Distortion (Reactive Load) <0.5% <0.9%
Output Impedance <0.015 ohm <0.015 ohm
Noise Reduction 100kHz – 2MHz >80dB 100kHz – 2MHz >80dB
Efficiency @1200 VA >85% >85%
Input Frequency 45 – 65 Hz 45 – 65 Hz
Under Voltage Limit Continuous -10% of setting 15 sec duration -15% of setting Continuous -10% of setting 15 sec duration -15% of setting
Over Voltage Limit Continuous 5% of setting 15 sec duration 10% of setting Continuous 5% of setting 15 sec duration 10% of setting
Energy Dissipation 2440J 3670J
Peak Current Surge 144,000A 84,000A
Max Surge Voltage 6,000V 6,000V
Clamp Level 330V 800V
DC Trigger Configuration Tip Positive Tip Positive
DC Trigger Voltage 5 – 15Vdc 5 – 15Vdc
eWAY Payment Gateway